Frequently Asked Question

Default 7802A computer settings

Last Updated 2 years ago

To gain access to the programming menu on the 7802A computer, press the 'P' button for 3 seconds and hear a beep. Use the Up/Down arrows to navigate to the program settings below. Press the 'S' button to set the value. Once done , press the 'P' button for 3 seconds to save and hear a beep.

Default program settings for MeloChicks incubators & Hatchers for the 7802A computer are

U13=OFF
U14=0.1 - Temp hysteresis
U15=?? - temp calibration - normally found on sticker on side computer box.
U20=H - H=heating, C=cooling
U21=1.0 - Humidity hysteresis
U22=01 - Humidity timer
U23=5.0 - Humidity calibration
U40=01 - (00=seconds, 01=minutes, 02=hours)
U41=45 - turner motor left mins
U42=01 - (00=seconds, 01=minutes, 02=hours)
U43=45 - turner motor right mins
U44=00
U45=00 - (00=seconds, 01=minutes, 02=hours)
U46=10 - exhaust fan run secs
U47=01 - (00=seconds, 01=minutes, 02=hours)
U48=20 - exhaust fan timer interval mins
U50=05
U60=02
U61=0.6 - Temp High Limits
U62=0.6 - Temp Low limits
U63=10.0 - Humidity High Limits
U64=10.0 - Humidity Low Limits
U65=01 - Buzzer


RESET COMPUTER : Keep〖P〗and 〖▲〗depressed simultaneously for 5 sec., the device displays “UnL”, press 【▼】 twice, the controller will reset all parameters to factory default settings.